30BA/30BB. What went wrong

N43 / N53 · NOXEM · DIAGNOSTICS

Select a technical image to view it in detail.

I have already written about overvoltage problems in the MSD80/81 ignition coil drive transistors. Fitting snubbers to the ignition coils solves that problem fundamentally. There is, however, a second design flaw, also made by the Siemens engineers. This time the article is more technical, because the problem itself is technical.

As a result of this flaw, fault code 30BA/30BB is stored and the injectors of one bank are switched off. Clearing the fault codes does not help, because the DME itself is damaged.

How the injectors are driven

Injector control is organized as follows:

  • The high-side switch is common to the whole bank.
  • The low-side switch is individual for each injector, and the “active” injector is selected through it.

Everything works well as long as the low-side switches are commutated correctly: the active injector is selected in time, then the high-side switch operates and supplies 130 V to the required injector. The low-side switches work in ZVS (Zero Voltage Switching) mode, so they have no dynamic switching losses.

If a low-side switch is damaged, the whole bank has to be switched off, because the high-side switch is common to the bank. Otherwise, because of the damaged low-side switch, the affected cylinder receives three times as much fuel, and at completely inappropriate moments.

Situations in which the failure starts

The fundamental problems begin in the following situations:

  • A cylinder is cut off (because of group misfires) and its low-side switch is disconnected at the moment the high-side switch is opening.
  • A low-side switch is disconnected before the high-side switch. Directly after the cutoff, or a moment later, the high-side switch is triggered. The high-side module then has no load and dU/dt is not limited, so it is very high. This case is described in detail below.
  • A DME shutdown, a DME restart or undervoltage occurs at the moment the high-side switch is triggered, but because of the cold or hot restart the low-side switch closes.
  • The injector has connection problems or internal damage.

What happens with an unloaded high-side switch

With zero load (the corresponding low-side switch is closed), the high-side switch is opened with a very high dU/dt. The maximum dU/dt at which a MOSFET is destroyed by secondary breakdown will probably not be reached. But because of the parasitic capacitance of the wires from the DME to the injectors, overvoltage spikes that significantly exceed Uds max are possible.

The second effect is that, at high dU/dt, the MOSFET can turn on parasitically through its reverse transfer capacitance, because Rgate is high at 100 Ω. For the IRF644, the datasheet gives typical values of Ciss = 1300 pF and Crss = 85 pF. Even a simple calculation shows (and real conditions will be worse) that at Uds of around 50 to 100 V the transistor can open, and will open, on its own.

The low-side MOSFET can then start to conduct, or sit in the active mode for a moment, until the gate charge is drained through Rgate. Heat dissipation rises rapidly, the gate is destroyed because its voltage exceeds the maximum allowed, and the transistor fails.

In the first and third situations above, it is the low-side switch that ends up as the active switch, not the high-side switch as intended in normal operation. The consequences are catastrophic: a rapid rise of Uds, overvoltage spikes and parasitic turn-on of the switch, the full set. This situation can really happen, and does happen, but the DME design does not account for it. It is a fundamental design failure.

Injector connection problems

Do NOT disconnect the injectors while the engine is running. Likewise, do not disconnect the ignition coils while the engine is running. If you need to disable cylinders, use a suitable test module.

To be honest, knowing that such a failure is possible, I cannot drive my BMW with confidence. This defect is a bomb with a burning fuse.

Solution

The solution is a snubber plus overvoltage protection for each low-side switch, consisting of:

  • an R (22 to 47 Ω, 3 W, Pulse series) and a C (33 nF, 250 V DC, polyester or polypropylene) connected in series;
  • a bidirectional 200 V, 600 W TVS diode connected in parallel.

Place the snubbers as close to the DME as possible, ideally at the low-side switches. They limit both dU/dt and Uds for the low-side switches. The minimum that should be implemented is TVS protection to limit Uds.

Replacement transistors

The “repairs” offered on the Internet, in which the damaged IRF644 transistors are replaced with the same type, are completely useless.

If the replacement is, for example, the FDB14N30, the situation is only slightly better: Ciss/Crss is 50, but Uds is only 300 V.

With the SiHB30N60 the situation is much better. It has Uds = 650 V and Ciss/Crss > 100, so it will survive voltage spikes much better and will not open on its own.

The ISL9V5045S3ST is also a good choice: Ciss/Crss > 100, and it has built-in overvoltage protection.

Schematics

Simplified schematic of injector control:

  • Q1 to Q6: low-side switches
  • Q7, Q8: high-side push-pull drivers (switches)
  • R1, R2: current-sensing resistors
  • INJ 1 to INJ 6: injectors

Schematics of the protection solution (4 or 6 pieces are required for N43/N53 engines):

  • Figures 1 and 2: solution 1 (Figure 2 is the critical minimum).
  • Figures 3 and 4: solution 2 (Figure 4 is the critical minimum).