Skip to content
Shop
Explore

INDEPENDENT BMW ENGINE EXPERTISE

BSD and waterpump

N43 / N53 · NOXEM · DIAGNOSTICS

Select a technical image to view it in detail.

This entry covers a case with a rare defect. It is also worth describing the symptoms that typically point to BSD problems on modern petrol engines.

The case

The patient was an E9X with an N55 petrol engine. Even with a new AGM battery, the car had power supply problems. The battery had been coded twice, the second time “just to make sure” after the problems appeared, but it was still close to “fainting”.

One morning the owner noticed that the water pump started running as soon as he unlocked the car, and kept running for a while after he locked it. Shortly after this symptom appeared, the electrical supply problems began.

The DME fault memory contained every possible fault related to the BSD data network.

What a dead BSD network does to N-series petrol engines

The following components are connected to BSD: the IBS, the oil quality/level/temperature sensor, the alternator and the water pump.

If the water pump receives no command over BSD (including the required flow rate), it runs in emergency mode at close to maximum power, to prevent the engine from overheating. With a damaged BSD, the pump cannot know when the engine is started or stopped. It simply runs whenever supply voltage is present.

Pump connection, using an N52 engine in an E60 LCI as the example:

The pump has four connections:

1. Ground 2. Main +12 V (terminal 30) 3. Power supply for the electronics 4. BSD data connection

How a LIN driver can block the network

The next image shows the block schematic of a typical LIN driver, the interface that lets a unit communicate with the rest of the network.

The LIN output connects to the LIN network:

  • Passive level (the unit is asleep or sends “0”): close to Ubat (12 V).
  • Active level (the master or another unit sends “1”): close to ground.

Every LIN client and the master has such a driver. If a unit loses its supply voltage, its LIN driver stays in the passive state and does not disturb the network. The same is true if the unit does not start for some other reason, for example a damaged MCU clock generator. Its driver is then also passive and does not interfere with the other clients.

The only way a LIN driver can paralyze communication for the other clients is damage to its TXD (transmit) transistor. Damage to the TXD buffer is theoretically possible but very unlikely.

The transistor whose failure blocks all LIN clients is marked in the schematic.

The scope picture differs depending on what is damaged:

  • If only the transistor is damaged, the LIN signal on the oscillogram reaches a maximum of about 0.5 to 0.8 V. This is the voltage drop across the diode connected in the transistor’s drain.
  • If the diode in series with the transistor is also damaged, no LIN signal is visible at all.

Such a defect is not typical, because LIN drivers are robust. Their output transistors tolerate 50 V on the LIN line and up to 1000 V in the human-body-model static discharge test. I can imagine only one possible cause: the signal from injectors or ignition coils reaching the LIN data line. Those signals can reach several hundred volts, and for ignition coils the dU/dt is also high.

I have seen similar damage elsewhere. This is how the CAN lines of NOx sensors and exhaust temperature sensors get damaged, for example. Unfortunately, BMW did not provide double insulation for the high-voltage wires of ignition coils or injectors.

Measurements on this car

Observing the LIN signal with an oscilloscope, I found the signal level strongly reduced in what should be the passive state.

With the vertical scale reduced to 500 mV/div, the signal amplitude is about 0.8 V instead of the required 12 V.

This time the damaged LIN driver was in the water pump itself. With the pump disconnected, the signal level on the BSD network became correct.

I also checked the rise and fall times of the BSD signal. They were correct, with no “half-level” signals and no sign of increased capacitive load.

Why the battery was draining

As mentioned above, a water pump that receives no BSD commands runs continuously as soon as it has power. These pumps can draw 500 to 700 W depending on the model, which means a current of 50 A or even more.

In addition, because BSD is not working, the DME does not receive (or calculate) how much energy is left in the battery. When the car is switched off, the pump stops only when the voltage in the DME/CAS reaches the critical minimum and terminal 30 is disconnected. This emergency mode is intended for cases where the IBS system does not work or fails. Even an ideal, fully charged battery is therefore drained almost empty very quickly.

This case is one more example of how important it is that the IBS/BSD system works correctly.

After the repair

The water pump was replaced:

BEYOND THE FAULT CODE

A clearer picture.
A better next step.

Get in touch
Enlarged technical image
Open original image