If a Lambda probe is damaged or clogged badly enough to give an incorrect signal, DME will most likely store an error message. This entry covers one symptom that shows probe aging before any error is recorded: increased PWM of the probe heating.
Example
The first screenshot shows the heating PWM of the probes:
The second shows the Nernst resistance (chemical efficiency) of the same probes:
The Nernst resistance is correct here. The correct INPA value is 0/256 Ohm. However, the heating PWM needed to reach this value is at least 20% higher than on the second probe, which I used for comparison.
What the increased PWM means
A probe in good condition reaches the required chemical efficiency at a normal PWM. A probe that cannot do so at the normal PWM forces DME to raise the heating. That is bad news: the probe will not endure this thermal overload for long. I recommend buying a new Lambda probe in good time and preparing to replace it.
How DME measures and controls this
DME measures the Nernst resistance of each probe about once per second. A current source connects the signal output to +5.0 V, and DME measures the resulting change in voltage.
According to the probe datasheet, the optimal Nernst resistance is 80 to 300 Ohm. INPA displays this value in steps of 256 Ohm, so the correct INPA reading is 0/256 Ohm. A reading of 512 Ohm is allowed for a short time.
The heating PWM is set from a control map, which takes into account the simulated exhaust gas temperature and the exhaust flow rate/pressure. An adaptation offset is added to this map. The offset is based on the difference between the measured Nernst resistance and the ideal value.