The term “leaking injector” covers several different defects. Here I describe the most common one: a hard microparticle lodged in the injector nozzle.

How foreign particles reach the injector

Even premium petrol can contain sand, debris and traces of other oil products. That is why filling-station pumps and the cars themselves have fuel filters. Not everything is filtered out, though, and some particles reach the fuel supply system and the injectors. Many are simply injected into the combustion chamber, but sometimes one stays in the injector.

If a foreign object gets stuck in the nozzle, the injector cannot close completely, and fuel keeps leaking through the nozzle even when it should be shut.

Sometimes the particle is flushed out after a while and the problem disappears as quickly as it appeared. If the defect lasted only a short time, the owner may not notice it at all. If it lasted longer, the MSD has most probably switched to an emergency mode, and the engine needs to be re-adapted to restore normal performance. In that case re-adapting is enough, and the injector does not have to be replaced.

This case is instructive because the injector that started leaking had the least wear of all. The nozzles in this engine have served for over 300,000 km, yet the defect appeared on one with only about 120,000 km.

Symptoms and first diagnostics

At first the engine showed increased, constant vibration at idle. After a while the idle became uneven, with occasional misfires.

In INPA no fault codes were stored yet, but there were some abnormalities. The LTFT offset of bank 2 was strongly negative (about -1.30 mg/stk, unlike the other bank). This means the total fuel quantity for the whole of bank 2 had to be reduced for some reason, which is one of the symptoms of an injector delivering too much fuel.

The next step was to check the injector adaptation data.

I opened the injector adaptations for idle in Stratified charge mode. The engine has NOXEM installed, and despite the considerable mileage it still runs in Stratified charge. The adaptations of the cylinder 5 injector are strongly negative, meaning its opening time has been cut sharply. This indicates an injector with a leak.

The engine then switched to Homogeneous mode, so I continued with the Rough run data.

The mechanical efficiency of cylinder 5 (shown in the menu as cylinder 2 by firing order) is strongly increased. In this software release, zero efficiency corresponds to about +6 units, so the efficiency of cylinder 5 is roughly 50 % higher than that of cylinders 4 and 6. The fuel quantity injected into this cylinder is clearly much higher than in the others.

At the same time, the live data confirm that the opening of this injector is 5 to 10 % shorter than on the other cylinders. Because the total fuel quantity for bank 2 was reduced, cylinder 4 or 6 started to misfire, since the mixture in those cylinders became lean. The constant vibration comes from the increased mechanical efficiency of cylinder 5.

Next I switched the engine to Stratified charge:

Rough run now shows the cylinder efficiencies almost evened out, and subjectively the vibration disappeared. The live data, however, show that the opening time of cylinder 5 in this mode is also half that of the others (0.10 ms against 0.20 ms for two other cylinders). With an opening about twice as short, the cylinder reaches the same efficiency as the “normal” cylinders.

After a while, fault codes were stored for problems maintaining the mixture on bank 2 and for the maximum correction range being reached on cylinder 5.

How the MSD80 handles injector adaptation

Several details of MSD80 behaviour matter here:

  • The algorithms that build the injector adaptations for Stratified charge and Homogeneous modes are completely separate.
  • Stratified charge mode allows wider “corridors” of permitted adaptations, and faster changes in flow rate (and therefore in opening time).
  • Homogeneous mode uses narrower adaptation corridors. New individual idle adaptations are switched off immediately when injector parameters change quickly, and the MSD works with the last available “correct” injector data.

Several parameters therefore confirm that the cylinder 5 injector delivers too much fuel in short-opening conditions such as idle. Hoping the injector would clear the foreign object by itself, I decided to wait a little and take no drastic action.

Next day

I started the cold engine (+6 °C) and everything looked correct.

Injector opening times:

Rough run data:

Everything looked acceptable, but the situation got worse as the engine warmed up. The explanation is simple. Cold fuel is more viscous and flows less well, including through the damaged injector. In addition, the cold engine needs 2 to 3 times more fuel to maintain idle, so the effect of the defect is 2 to 3 times smaller. As the engine warms up, opening times become shorter and the fuel becomes thinner, so the impact of the defect grows.

Once the engine was warm, the defect returned in full and did not go away over the next several engine hours, so I decided to replace the injector. The removed injector was cleaned and kept as an emergency spare.

Further checks

If you suspect a leaking injector, check the injector live data and the multiplicative adaptations. In this case the multiplicative adaptation value for cylinder 5 is correct, which is good news.

The second menu worth checking is the chemical tests of the injectors:

The data in these menus show relative differences (changes in the cylinder tests). The measuring injector, for both short and long openings, has not changed significantly since the previous tests. This is further confirmation that the injector has no serious defect. If cleaning gets the foreign object out of the nozzle, the injector can serve for a long time.

Misleading signs from the lambda probes

Some details here can mislead you. First, look at the control probe voltage for bank 2.

It is too high, since the correct voltage is about 0.75 V. The control probe indicates a rich mixture (richer than stoichiometric). Part of the fuel that was injected into the exhaust unmixed was not detected by the wideband probe. It mixes in the exhaust and burns the small excess of air in the catalytic converters. When the MSD sees that the control probe indicates a mixture that is too rich, it also recalibrates the wideband probe so that its readings match this enriched mixture. The wideband probe then indicates Lambda 1.00 (2.00 V) even though the real Lambda is lower, meaning the mixture is rich.

Here is the confirmation of the rich mixture:

The average Lambda is 0.96. This means bank 2 runs rich (Lambda around 0.92, with at least 8 % excess fuel).

And here is the moment of the lambda probe test:

Even though the wideband probe appears to give a correct reading of Lambda 1.11 (lean mixture, about 11 % excess air), the control probe still indicates a rich mixture (about 0.80 V). This is not a probe problem. It is only a consequence of the leaking injector, namely the incorrect calibration of the wideband probe.

Recalibration of the wideband probe

On the second day of the defect described above, just after warm-up, the wideband probe of bank 2 indicated a stoichiometric mixture (2.00 V, Lambda 1.00). The control probe voltage, however, was slightly low at about 0.60 V, as if the mixture were slightly leaner than necessary. This low voltage is a consequence of the previous day’s defect: the wideband probe was incorrectly calibrated.

The situation after 2 minutes:

The wideband probe is now calibrated correctly, so the MSD did its job perfectly. It indicates Lambda 1.00 (2.00 V), and the control probe voltage is exactly 0.75 V.

Conclusions

  • Hard microparticles mixed into the fuel can cause an injector to leak. Piezo injectors are more sensitive to this than injectors of the old type.
  • This problem, which is not really an injector defect, can happen at any moment, even with a brand new injector right after installation.
  • It is reckless to replace the injector immediately at the first sign of such a problem, and even more so to replace all the injectors. If the injector can be cleaned, do it. If the cleaning succeeds, the injector can be used again, because this defect has no negative effect on its later function.
  • A leaking injector causes many related problems, including incorrect probe signals, fault codes for mixture maintenance and misfires. The diagnostics therefore have to be carried out carefully and thoroughly.

Correct diagnostics of injector problems can save you several thousand EUR. The most common problem, a microparticle in the piezo injector, can usually be solved by cleaning the injector and leaves no negative effect on its further performance.

After the repair

P.S. Some screenshots after the repair (injector replaced and coded, engine re-adapted):