Skip to content
Shop
Explore

INDEPENDENT BMW ENGINE EXPERTISE

Damages of the Lambda probes

N43 / N53 · NOXEM · DIAGNOSTICS

Select a technical image to view it in detail.

In this entry I summarize the types of damage that affect wideband probes and describe how to identify each defect from live diagnostic data. I cover both the regulating (pre-cat) probes and the NOx sensors, in OEM and NOXEM versions. The menu references are for N43/N53 (E series) engines, but equivalents exist for every petrol engine.

Defect of the calibration resistor

The calibration resistor sits in the probe plug. This defect is possible only for Bosch LSU 4.9 (4.2) probes. It is NOT possible for Bosch LSU ADV probes or for NOx sensors.

Cause. Contact with the calibration resistor in the probe plug is lost.

Consequences.

  • The probe’s sensitivity away from the stoichiometric mixture (Lambda 1.00) is greatly increased. For example, instead of Lambda 1.10 the probe reports 1.30, and instead of 0.95 it reports 0.82.
  • The probe corrects the fuel mixture wrongly and overcompensates, so hunting and instability are possible.
  • Possible error messages concern the mixture (both lean and rich) and the probe trim control. Misfires may also occur.
  • The DME may switch to open-loop mode.

Identification. This is relatively simple on N53 (E series) engines, using the probe test block. It is difficult on other engines.

Menu.

  • N53 engines: ../F9/F3. The Lambda correction of the pre-cat probes in the probe test block should be 0.90/1.10 (±0.02).
  • All engines: ../F5/F6. Lambda shows very large, rapid deviations from the target. For example, in homogeneous mode Lambda swings quickly beyond 1.00 ±0.05.

Remarks. The Nernst resistance (chemical efficiency of the probe) is correct.

Damage to the ceramic element

The active element of the probe is a ceramic plate. The typical damage is microcracks, but more severe defects are possible, up to complete break-up of the plate. The fault is possible for Bosch LSU 4.9 (4.2), LSU ADV and NOx sensors (both OEM and NOXEM).

Cause. Thermal shock (water condensate in the exhaust) or mechanical damage (a mechanical hit to the exhaust, or an explosion of unburned fuel).

Consequences. The damage is permanent and the probe stops working. It indicates Lambda 1.00 in all driving conditions. The DME detects an implausible Nernst resistance, records an error message about the probe temperature (heating) and switches the heating off.

Identification. This is simple on all engines. The probe indicates Lambda 1.00 in all driving conditions, including overrun, and its status in ISTA D is “Not ready”.

  • OEM NOx sensor: status “Not ready”, plus error messages from self-diagnostics.
  • NOXEM: reports Lambda binary 500 ±10 mV. The status in ISTA D may be “Not ready”.

Menu.

  • Pre-cat probes: ../F5/F6 shows Lambda at 1.00 all the time, including overrun. ../F5/F2/F6 shows the Nernst resistance at its maximum value.
  • OEM NOx sensors (Online mode): ../F5/Shift+F2/F1 shows Lambda binary constant, but different from 1200 mV. Lambda linear is constant in all driving conditions, including overrun.
  • NOXEM (Online mode): ../F5/Shift+F2/F1 shows Lambda binary 500 ±10 mV and Lambda linear 1.00 in all driving conditions, including overrun.

Chemical poisoning

Poisoning is possible for Bosch LSU 4.9 (4.2), LSU ADV and NOx sensors (both OEM and NOXEM).

Cause. The most common poisoning agent is unburned fuel. Less often the cause is other chemical substances, such as fuel additives or exhaust-cleaning sprays injected directly into the exhaust. Sprays used while replacing the probe or repairing the exhaust system (for example WD40) can also poison it. The poisoning creates a current leak in the Nernst cell of the probe and disrupts its correct operation.

Consequences. The probe’s reference (at Lambda 1.00) becomes wrong. Typically the probe indicates increased Lambda, from 1.50 up to clean-air values of 20 .. 30. The defect can be sporadic: the probe sometimes “comes back to life” but periodically gets “sick” again.

Menu.

  • Pre-cat probes: ../F5/F6. The Lambda value rises rapidly above what is genuinely possible and can reach the maximum value (16). If the probe heating is switched off, the probe reports Lambda 1.00 in all modes, including overrun.
  • NOx sensors (Online mode): ../F5/Shift+F2/F1. Lambda linear is strongly increased and can reach the maximum value (32).

Remarks. The chemical efficiency of the probe is correct. With small or moderate poisoning, the probe may “recover” over a longer period. It cleans up faster if it is warmed up to working temperature.

Clogging

Clogging is possible for Bosch LSU 4.9 (4.2), LSU ADV and NOx sensors (both OEM and NOXEM).

Cause. The “measuring” openings or the cells of the ceramic plate are mechanically clogged with combustion products that have got into the exhaust, typically fuel contamination or oil. As a result, air and/or fuel residue reaches the probe only partially, or only after a long time. The probe gradually becomes “slower” and “less sensitive”.

Consequences.

  • The quality and precision of mixture control get worse.
  • The reported Lambda may no longer match the true value at Lambda 1.00, in the direction of either a rich or a lean mixture.
  • With a more obvious defect, the DME records error messages about probe trim problems, reduced Lambda in overrun, slow response and plausibility.

Identification. The simplest approach is to test the probe’s ability to detect clean air in overrun mode.

Menu.

  • Pre-cat probes: ../F5/F6. Lambda should reach 16 in overrun mode. With a clogged probe the reported Lambda is strongly decreased.
  • NOx sensors (Online mode): ../F5/Shift+F2/F1. Lambda linear should be 15 .. 32 in overrun mode, and a reduced value down to 8 .. 10 is still allowed. With a clogged sensor the reported Lambda is significantly lower.

Remarks. The chemical efficiency of the probe is correct.

Figures

  • [1] Defect of the calibration resistor
  • [2] Mechanical damage to the ceramic element
  • [3] Poisoning of the probe
  • [4] Clogging of the probe
  • [5] Correct curve

BEYOND THE FAULT CODE

A clearer picture.
A better next step.

Get in touch
Enlarged technical image
Open original image