Skip to content
Shop
Explore

INDEPENDENT BMW ENGINE EXPERTISE

Virtual probe. Part 2

N43 / N53 · NOXEM · DIAGNOSTICS

Select a technical image to view it in detail.

First part of this entry: read here.

This entry summarizes what I know about at least one cause of this problem and at least one solution.

Affected vehicles

The problem affects BMW vehicles with N43 series engines that have three Lambda probes: two probes upstream of the CO catalytic converters, and one control probe shared by both banks.

The problem

The DME stores error messages for the control probe of bank 2 (2C6C and 2C7F). These vehicles do not have a bank 2 control probe. The common control probe responds as the bank 1 probe.

After storing the error, the DME keeps running in a heavy limp mode:

  • It does not perform throttle adaptations or fuel mixture adaptations for the banks.
  • It does not measure the chemical efficiency of the injectors in Homogeneous mode.
  • It skips many other service procedures.

As a result, the fuel mixture in the cylinders is wrong and the exhaust system (CO catalytic converters) is overloaded. Misfires start, the engine shakes, the idle is unstable, power is lost, and CO/HC emissions in the exhaust rise.

Cause

The cause is fundamental bugs in the DME software. Even the latest releases, for example those intended for PG31/PG32, contain them, so updating to the newest release will not help. You can try older releases, or releases intended for other FR. Unfortunately, the defect is not common enough for complete information on the defective releases to exist, and no release is known to work correctly.

How the fault develops

1. There is some trouble with the fuel mixture (for example leaking injectors, HPFP problems, air leaks in the intake manifold or exhaust) or misfires. The DME then urgently needs to trim the wideband probes. 2. Fuel reaching the exhaust because of the incorrect mixture (the problems in step 1) poisons the probe of the NOx sensor. The leakage current in its Nernst cell increases, so the sensor reports a strongly increased linear Lambda and a lowered binary Lambda. 3. In the next driving session, the engine runs after the error messages were deleted. Alternatively, the mixture or misfire problems were solved, the old adaptations were deleted, and the engine re-adaptation procedure is running. The sequence is then:

  • While the engine warms up (reaching 60 to 65 °C), the DME switches on Stratified charge (the engine works in full-functionality mode).
  • Once all conditions for switching the NOx sensor online are met (engine temperature, exhaust temperature, temperature of the NOx sensor probe, and a time delay to avoid condensate), the DME commands the NOx sensor on.
  • When the NOx sensor switches on (its probe warms up, it goes online and starts sending live data), the DME sees that the Lambda value reported by the sensor is outside the allowed corridor. It stores error 30DE (Lambda value correlation) and switches off Stratified charge.

Note: the same issue can potentially be provoked by other stored NOx sensor errors (30E2, 30E4, 30E6, 30DA, 30DC, etc.).

Up to this point the DME behaves normally. From here on, the gross errors described above begin.

What the DME does during wideband probe trimming

If the DME status bits record that the wideband probes must be trimmed immediately, the DME performs the trim as soon as it has switched to Homogeneous mode. The preconditions are even driving conditions (60+ km/h) and no other problems in the DME.

From the first seconds, the procedure is clearly performed completely wrong.

In the first stage, the DME creates a lean mixture in both banks in turn, starting with bank 1:

If all Lambda probes are working, the control probe of bank 1 (the real one) correctly indicates a lean mixture (its voltage is below 0.10 V).

Note: the control probe of bank 2 does not exist; it is an unused DME ADC input. It indicates a RICH mixture, meaning its voltage is above 0.80 to 0.90 V.

After a short moment, the DME enriches the mixture in both banks in turn:

The bank 1 control probe correctly indicates a rich mixture (voltage above 0.80 V), but the virtual bank 2 probe indicates a LEAN mixture (voltage 0.00 V).

Note: a control probe reading of 0.00 V means a short circuit to GND. The Nernst (internal) resistance of the control probe is not 0 Ω but several hundred ohms. The DME input is connected through a resistor to a 0.42 V reference source, which is used to check the ADC input for short circuits and the probe connection. Even with a completely lean mixture, the current through this resistor creates a slight voltage offset, so the DME will measure at least 0.02 V. A correct control probe signal therefore cannot be 0.00 V.

Sometimes the DME goes even further. For a moment it creates a lean mixture (Lambda up to 1.20 to 1.25) and a rich mixture (Lambda down to 0.75 to 0.80) in both banks. In this test stage too, the real probe reports the appropriate mixture while the virtual probe reports the opposite.

After this procedure, the DME stores errors 2C6C and 2C7F, which refer to the bank 2 control probe. In the attributes of 2C7F, the 0.00 V reading is visible:

It seems the DME does not see the control probe indications at all. Alternatively, when trimming both wideband probes, it mixes the true and correct data of the real probe so heavily with the incorrect indications of the non-existent probe that it cannot trim bank 1 correctly. The trim of the bank 2 wideband probe ends in a complete crash.

Such large deviations from the correct mixture (Lambda 1.00) are not normal. They put additional load on the exhaust (CO catalytic converter) and repeatedly poison the NOx probe, so it cannot recover.

Attempts to fix the software

  • I flashed the newest software release. Unsuccessful.
  • After the software update, error 2AF3 (incorrect coding) suddenly appeared on this vehicle, so I rewrote the coding in the DME and related ECUs. Unsuccessful.
  • I forcibly rewrote all memory sectors using WinKFP. Unsuccessful.
  • I tried the previous software release. Unsuccessful.
  • I took a DME and CAS from another vehicle, flashed the latest software release, and updated the coding to match the current vehicle. Unsuccessful.

The solution

At this point I took a desperate step. I decided to eliminate every other remaining problem with the engine, on the idea that an engine running without error messages, and with correct signals from all subsystems and sensors, would at least be minimally tested and should be able to perform correctly. The only problem left was the inappropriate Lambda readings from the NOx sensor.

I replaced the NOx sensor with a new one that reports a correct Lambda. On the next drive, after starting the engine, the DME behaved as before. After a minute or two in Stratified charge, it switched to Homogeneous mode to trim the wideband Lambda probes. This time the trim completed successfully within 15 to 20 seconds. Interestingly, the virtual probe’s indications now corresponded to the actual mixture.

It seems BMW engineers modified other sections of the software, unrelated to NOx system management, without even basic functional checks and debugging. Unfortunately, BMW stopped updating this DME software in 2012.

Conclusions

This is one more fundamental reason why the NOx system must be in working order. NOx sensor problems can cause a complete breakdown of the fuel mixture, unavoidable and even illogical error messages about the Lambda probes, and eventually overloaded and damaged CO catalytic converters. They can also make it impossible to pass the TI. Replacing the Lambda probes will of course give no results. According to customers, after the probes are replaced, workshops usually propose replacing the injectors, the HPFP and every other expensive part, without any warranty on the result.

In this case, the usual approach of cleaning the contaminated NOx sensor probe while driving will not work. The DME behaves so incorrectly that the NOx probe (and the other probes) will be repeatedly contaminated with large amounts of leftover fuel. The only repair strategy is to replace the NOx sensor (or its probe) immediately, while making sure that no problems remain with the injectors, HPFP or other systems that could damage the probes.

BEYOND THE FAULT CODE

A clearer picture.
A better next step.

Get in touch
Enlarged technical image
Open original image