The UK, like a few other countries, drives on the “wrong” side of the road. If an owner wants to use such a car long-term in a country that drives on the right, it has to be converted. I have seen many advertisements offering a “high-quality conversion”, but none offering “we will break your car”.

This entry describes a conversion carried out by “professionals”. I won’t comment on the mechanical work, as I don’t have enough information. I was asked to help with the electronic problems.

History of the car

After the conversion, all the windows opened the “wrong” way and the door icons in the KOMBI were incorrect. That had already been corrected before I got involved. The SRS system, however, had been amputated. All airbags had been uncoded with NCS, the wires to the airbags were destroyed, and “false plugs” had been installed. Evidently several “specialists” had worked on this car, one after another.

Over the last two years the car has spent more time in workshops than on the road. None of the many specialists solved the problem. Someone even opened the DME and glued it shut again with silicone, apparently believing it was to blame.

Symptoms

  • The DME fault memory regularly recorded a fault for the wideband probe trim. The owner had replaced two probes (only Bosch/OEM), without result. I tested both removed probes, which had been written off as damaged, and they were in excellent condition.
  • A fault for the accelerator pedal kept appearing. Replacing the pedal module twice changed nothing.
  • The car could not pass the technical inspection because its exhaust emissions exceeded the limit.

The owner’s direct costs have reached four digits, all without success.

Lambda probe measurements

I assume readers of my blog already know what the Nernst resistance of a probe is and what it indicates, so I will only touch on it briefly.

In INPA (../F5/F2/F6) both the wideband and the control probe show serious problems, and the control probe’s condition is critical. Its Nernst resistance is above 35000 Ohm, where the correct value is about 100 times lower. The probe has very poor chemical efficiency.

Logically, its voltage is then insufficient and the trim procedure of the wideband probe fails, which is why the trim fault is stored. It does NOT mean the wideband probe is damaged. Unfortunately all the specialists took exactly that view and replaced the wideband probe, twice, as I mentioned, without any result.

The wideband probe’s efficiency is also reduced. The picture shows the best case. Typically its Nernst resistance is 1500 to 2000 Ohm, 7 to 10 times above the norm. There was one more odd symptom: when the DME starts heating the narrowband probe, the wideband probe’s Nernst resistance rises to 7000 to 9000 Ohm. The probes are evidently connected somehow, which is more than strange.

My first assumption was a damaged control probe. I replaced it with a used OEM probe as a test, and nothing changed.

Looking at the signals

We then began a more serious investigation. This is how the measurements were done:

One technician was below the car, in the pit. The other watched the INPA live data and the oscilloscope.

This is the control probe heater signal, measured at the DME plug:

How do you like that signal? Ground shows “waves” of around 2 V, and the supply has “notches” of +12 V. Notches like that point to a poor-quality power supply, and ground waves to incorrect grounding.

Here is the heater signal measured directly at the probe plug:

It looks something like this:

The ground waves are gone, but the +12 V looks very strange. The probe’s power supply must be connected completely incorrectly. The connection point was clearly badly chosen, and the wires are too thin.

Such a supply can cause heating problems (chemical efficiency 20, 30 or 40 % below optimal), but it cannot explain a Nernst resistance 100 times too high. There had to be other causes.

As the investigation continued, things became more interesting. INPA live data said the mixture was very rich (Lambda around 0.9), because the wideband trim had failed so many times, yet the wideband probe voltage was only around 0.5 V. At the same moment the oscilloscope, measuring at the probe plug, showed this:

The voltage is not 0.5 V but 0.85 V. So the probe’s output at its plug is correct, and the problem must lie in the connection between probe and DME.

While I was moving the tangle of wires, the control probe’s Nernst resistance suddenly started to drop quickly:

It is now only around 3000 Ohm.

More interesting still, the mixture became slightly lean and the control probe voltage moved closer to the correct value:

The signal shape now also shows the moments when the DME measures the Nernst resistance:

The cause was now clear. The conversion had evidently been done to a “very high quality”. There was no other option: everything had to be opened up.

What the conversion did to the wiring

This is how the conversion looks. The wires change colour in random sequence, and textile insulation tape has been used where proper insulation belongs:

I kept digging:

The wire held by the technician is the power supply to the lambda probes, which should have a cross-section of 2.5 mm². The “new” wire set has additions and branches coming off it. Cross-section? The people who did the conversion obviously never heard of it.

As a result the probes “ground” each other, meaning their power supplies interact. When the DME starts heating the control probe, the heating voltage of the wideband probe drops and its chemical efficiency falls. Because of this unexpected interaction the DME also cannot adapt the probes’ heating maps. Choosing the wrong piece of wire guaranteed a chain of fundamental problems.

The installers missed a second point. In the OEM design each probe has its OWN, independent power supply wire. Not knowing why, they simply used one common wire. A seemingly small detail changed everything.

Here is the schematic:

As you can see, EACH probe has its own power supply wire (orange).

The “specialists” also had no idea why some wires are twisted in pairs, and did not bother to twist them. That makes it very clear why there are fault messages about CAN communication.

Here the wires are not soldered but simply twisted together.

Repair and aftermath

The only possible solution is to replace the whole wireset with parts from a donor car. That is laborious work, and it is only necessary because the original conversion was done by complete fools. Restoring the SRS (airbags, pyro-cartridges, coding of the SRS module) is still ahead as well.

I hope the new wireset will also cure the accelerator pedal problem, though that fault still has to be addressed properly.

The worst part is that surprises can appear in any module the “specialists” touched, whether a sensor, an actuator connection or a switch.

Twenty-four hours later, with the same car and the same probes but the new wireset, all problems with both lambda probes had disappeared as if they had never existed:

After 48 hours the car “lost” its electric fan. The cause was an extended wire that had been only twisted, not soldered.

After 72 hours the active steering and the steering angle sensor failed.

How many more surprises are still waiting?